{"id":1899,"date":"2025-02-27T15:30:18","date_gmt":"2025-02-27T14:30:18","guid":{"rendered":"https:\/\/aid-foundation.com\/?post_type=article&#038;p=1899"},"modified":"2026-03-30T15:40:34","modified_gmt":"2026-03-30T13:40:34","slug":"reduced-diameter-implants-in-the-molar-region-alerting-interim-findings-from-a-clinical-trial","status":"publish","type":"article","link":"https:\/\/aid-foundation.com\/fr\/knowledge-hub\/landmark-study\/peri-implantite-un-probleme-commun-et-croissant-en-dentisterie-3-2\/","title":{"rendered":"Implants \u00e0 diam\u00e8tre r\u00e9duit dans la r\u00e9gion molaire : Alerting interim findings from a clinical trial"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Implants \u00e0 diam\u00e8tre r\u00e9duit dans la r\u00e9gion molaire : Alerting interim findings from a clinical trial<\/h2>\n\n\n\n<p><a href=\"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/clr.14179\" target=\"_blank\" rel=\"noreferrer noopener\"><em>Zumstein K, et al. Clinical performance of monolithic zirconia crowns on titanium-zirconium reduced-diameter implants in the molar area : Interim data at three years of a randomized controlled trial. Clin Oral Implants Res. 2023;34(12):1354-1362.<\/em><\/a><\/p>\n\n\n\n<p>Recommand\u00e9 par Dr. med. dent. Konrad Meyenberg<\/p>\n\n\n\n<div class=\"wp-block-group has-accent-background-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading has-white-color has-text-color\"><strong>Enseignements de cette \u00e9tude pour la pratique clinique<\/strong><\/h4>\n\n\n\n<p class=\"has-medium-font-size\">Based on the study's findings, it cannot be recommended to replace individual molars by a single reduced-diameter implant.<\/p>\n<\/div>\n\n\n\n<p class=\"has-medium-font-size\">Les implants \u00e0 diam\u00e8tre r\u00e9duit (\u22643,5 mm) peuvent \u00eatre utiles dans certaines situations, et des \u00e9tudes ont fait \u00e9tat de taux de survie \u00e9lev\u00e9s. Cependant, les donn\u00e9es \u00e0 long terme sur les implants de diam\u00e8tre r\u00e9duit supportant des restaurations sont lacunaires, en particulier dans la r\u00e9gion post\u00e9rieure. Dans cette optique, un groupe de l'Universit\u00e9 de Zurich a r\u00e9alis\u00e9 un essai clinique randomis\u00e9 d'une couronne en zircone monolithique contre une couronne en porcelaine fusionn\u00e9e au m\u00e9tal (PFM), toutes deux sur un implant en titane-zirconium de diam\u00e8tre r\u00e9duit (Straumann Roxolid, Tissue Level, Standard Plus, diam\u00e8tre 3,3 mm, col normal). Ils rapportent leurs r\u00e9sultats provisoires 3 ans apr\u00e8s la chirurgie.<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer is-style-normal\"><\/div>\n\n\n\n<blockquote class=\"wp-block-quote blockquote-with-image align\">\n<figure data-no-zoom=\"true\" class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"500\" height=\"500\" src=\"https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311.jpg\" alt=\"\" class=\"wp-image-883\" srcset=\"https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311.jpg 500w, https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311-300x300.webp 300w, https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311-150x150.webp 150w, https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311-12x12.webp 12w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Le Dr. med. dent. Konrad Meyenberg<\/figcaption><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote\">\n<p class=\"has-accent-color has-text-color\"><em><strong><em><em>L'exp\u00e9rience avec les implants de diam\u00e8tre r\u00e9duit (3,5 mm ou moins) pour les implants monoblocs dans la r\u00e9gion molaire est limit\u00e9e.<\/em><\/em><\/strong><\/em><\/p>\n<\/blockquote>\n<\/blockquote>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer is-style-normal\"><\/div>\n\n\n\n<p class=\"has-medium-font-size\">Un total de 76 patients ont \u00e9t\u00e9 randomis\u00e9s et 59 ont suivi le suivi \u00e0 3 ans (27 avec la couronne en zircone monolithique et 32 avec la couronne PFM). Au cours d'un suivi moyen de 36,9 mois, le taux de survie des implants \u00e9tait de 80%, avec 14 implants perdus - deux chez les femmes et 12 chez les hommes. Notably, three implants in the PFM group were lost with no signs of inflammation, and six PFM crowns and five monolith zirconia crowns were lost due to implant fracture.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure data-no-zoom=\"true\" class=\"wp-block-image alignright size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"624\" height=\"196\" src=\"https:\/\/aid-foundation.com\/wp-content\/uploads\/2025\/02\/reduced-diameter-implants-in-the-molar-region.png\" alt=\"\" class=\"wp-image-1936\" style=\"aspect-ratio:3.183673469387755\" srcset=\"https:\/\/aid-foundation.com\/wp-content\/uploads\/2025\/02\/reduced-diameter-implants-in-the-molar-region.png 624w, https:\/\/aid-foundation.com\/wp-content\/uploads\/2025\/02\/reduced-diameter-implants-in-the-molar-region-300x94.webp 300w, https:\/\/aid-foundation.com\/wp-content\/uploads\/2025\/02\/reduced-diameter-implants-in-the-molar-region-18x6.webp 18w\" sizes=\"(max-width: 624px) 100vw, 624px\" \/><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size\">Des complications proth\u00e9tiques n'ont \u00e9t\u00e9 rapport\u00e9es qu'avec les couronnes PFM et comprenaient quatre cas de fractures mineures en c\u00e9ramique. L'usure occlusale \u00e9tait plus fr\u00e9quente avec les couronnes PFM (n=18) qu'avec les couronnes en zirconium monolithique (n=9) ; des contacts proximaux manquaient en m\u00e9sial sur 5 couronnes implantaires et en distal sur 4 couronnes implantaires. Les scores de satisfaction des patients \u00e9taient \u00e9lev\u00e9s dans les deux groupes.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<blockquote class=\"wp-block-quote blockquote-with-image align\">\n<figure data-no-zoom=\"true\" class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"500\" height=\"500\" src=\"https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311.jpg\" alt=\"\" class=\"wp-image-883\" srcset=\"https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311.jpg 500w, https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311-300x300.webp 300w, https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311-150x150.webp 150w, https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311-12x12.webp 12w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Le Dr. med. dent. Konrad Meyenberg<\/figcaption><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote\">\n<p class=\"has-accent-color has-text-color\"><em><strong><em><em><em>The present study questions the following 3 paradigms : 1. the geometric design of the implant itself is not so important, the more important is the material (pure titanium versus titanium-zirconium) ; 2. overloading as a reason for implant loss does not exist ; 3. individual molars can be replaced with diameter-reduced single tooth implants.<\/em><\/em><\/em><\/strong><\/em><\/p>\n<\/blockquote>\n<\/blockquote>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size\">Les r\u00e9sultats de l'\u00e9tude ont \u00e9t\u00e9 quelque peu surprenants. Le taux de survie des implants \u00e9tait plus faible que celui rapport\u00e9 dans la litt\u00e9rature, et les auteurs sugg\u00e8rent que c'est parce que les implants de diam\u00e8tre r\u00e9duit sont plus souvent plac\u00e9s dans la r\u00e9gion ant\u00e9rieure. Des forces occlusales traumatiques ont \u00e9t\u00e9 sugg\u00e9r\u00e9es comme \u00e9tant \u00e0 l'origine de la perte aseptique de l'implant. Toutefois, les observations de suivi de l'\u00e9tude n'ont pas permis de recueillir des informations pour soutenir ou rejeter cette th\u00e9orie. En ce qui concerne les fractures d'implants, les auteurs notent que les fractures se sont produites sous le canal interne de la vis dans tous les cas. Comme les fractures se sont produites plus souvent chez les hommes que chez les femmes, la surcharge biom\u00e9canique est une cause possible.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<blockquote class=\"wp-block-quote blockquote-with-image align\">\n<figure data-no-zoom=\"true\" class=\"wp-block-image size-full\"><img decoding=\"async\" loading=\"lazy\" width=\"500\" height=\"500\" src=\"https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311.jpg\" alt=\"\" class=\"wp-image-883\" srcset=\"https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311.jpg 500w, https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311-300x300.webp 300w, https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311-150x150.webp 150w, https:\/\/aid-foundation.com\/wp-content\/uploads\/2023\/10\/Konrad-Meyenberg-202311-12x12.webp 12w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Le Dr. med. dent. Konrad Meyenberg<\/figcaption><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote\">\n<p class=\"has-accent-color has-text-color\"><em><strong><em><em>Les auteurs de l'\u00e9tude concluent en soulignant que les fabricants devraient s'acquitter de leur obligation de r\u00e9aliser des tests de simulation appropri\u00e9s et cliniquement pertinents avant d'approuver l'indication d'un type d'implant. De cette mani\u00e8re, des \u00e9tudes \u00e9thiquement discutables peuvent finalement \u00eatre \u00e9vit\u00e9es.<\/em><\/em><\/strong><\/em><\/p>\n<\/blockquote>\n<\/blockquote>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size\">En raison du faible taux de survie, les auteurs ne peuvent pas recommander l'utilisation d'implants de diam\u00e8tre r\u00e9duit dans les sites molaires. Bien que la p\u00e9riode d'observation cliniquement courte soit une limite de cette \u00e9tude, le suivi final \u00e0 5 ans devrait apporter d'autres informations pr\u00e9cieuses sur l'utilisation post\u00e9rieure des implants de diam\u00e8tre r\u00e9duit.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Les implants \u00e0 diam\u00e8tre r\u00e9duit (\u22643,5 mm) peuvent \u00eatre utiles dans certaines situations, et des \u00e9tudes ont fait \u00e9tat de taux de survie \u00e9lev\u00e9s. Cependant, les donn\u00e9es \u00e0 long terme sur les implants de diam\u00e8tre r\u00e9duit supportant des restaurations fixes sont lacunaires, en particulier dans la r\u00e9gion post\u00e9rieure.<\/p>","protected":false},"featured_media":1936,"template":"","article_cat":[23],"acf":[],"_links":{"self":[{"href":"https:\/\/aid-foundation.com\/fr\/wp-json\/wp\/v2\/article\/1899"}],"collection":[{"href":"https:\/\/aid-foundation.com\/fr\/wp-json\/wp\/v2\/article"}],"about":[{"href":"https:\/\/aid-foundation.com\/fr\/wp-json\/wp\/v2\/types\/article"}],"version-history":[{"count":16,"href":"https:\/\/aid-foundation.com\/fr\/wp-json\/wp\/v2\/article\/1899\/revisions"}],"predecessor-version":[{"id":2173,"href":"https:\/\/aid-foundation.com\/fr\/wp-json\/wp\/v2\/article\/1899\/revisions\/2173"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aid-foundation.com\/fr\/wp-json\/wp\/v2\/media\/1936"}],"wp:attachment":[{"href":"https:\/\/aid-foundation.com\/fr\/wp-json\/wp\/v2\/media?parent=1899"}],"wp:term":[{"taxonomy":"article_cat","embeddable":true,"href":"https:\/\/aid-foundation.com\/fr\/wp-json\/wp\/v2\/article_cat?post=1899"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}